35537
Variation of Temperature in Incubation System Following Pump Failure with no Water Reservoir Trough 1 Incubators 16 and 32
Variation of Temperature in Incubation System Following Pump Failure with no Water Reservoir Trough 1 Incubators 16 and 32
Entity
Published / External
30878
Temperature - Impact of chiller failure on the short-term temperature variation in the incubation of salmonids
Data Set
Planned
Trough 1, Incubators 16 and 32.
Spreadsheet
Yes
PARR
Trough 1, Incubators 16 and 32.
1
Count
NUMBER
No
No
Active
Measurement counter. Units for values are #.
NUMBER
#
2
Data/Time
DATE
No
No
Active
Time of measurement. Units for values are days and minutes.
DATE
days and minutes
3
Up_16B_Rep_1
NUMBER
No
No
Active
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 1-First trough receiving chilled water, Incubator 16-Last incubator on right side of Trough 1; Replicant #1. Units for values are C.
NUMBER
C
4
Up_16B_Rep_2
NUMBER
No
No
Active
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 1-First trough receiving chilled water, Incubator 16-Last incubator on right side of Trough 1; Replicant #2. Units for values are C.
NUMBER
C
5
Up_16B_Rep_3
NUMBER
No
No
Active
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 1-First trough receiving chilled water, Incubator 16-Last incubator on right side of Trough 1; Replicant #3. Units for values are C.
NUMBER
C
6
Up_32B_Rep_1
NUMBER
No
No
Active
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 1-First trough receiving chilled water, Incubator 32-Last incubator on left side of Trough 1; Replicant #1. Units for values are C.
NUMBER
C
7
Up_32B_Rep_2
NUMBER
No
No
Active
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 1-First trough receiving chilled water, Incubator 32-Last incubator on left side of Trough 1; Replicant #2. Units for values are C.
NUMBER
C
8
Up_32B_Rep_3
NUMBER
No
No
Active
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 1-First trough receiving chilled water, Incubator 32-Last incubator on left side of Trough 1; Replicant #3. Units for values are C.
NUMBER
C
9
Down_16B_Rep_1
NUMBER
No
No
Active
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 1-First trough receiving chilled water, Incubator 16-Last incubator on right side of Trough 1; Replicant #1. Units for values are C.
NUMBER
C
10
Down_16B_Rep_2
NUMBER
No
No
Active
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 1-First trough receiving chilled water, Incubator 16-Last incubator on right side of Trough 1; Replicant #2. Units for values are C.
NUMBER
C
11
Down_16B_Rep_3
NUMBER
No
No
Active
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 1-First trough receiving chilled water, Incubator 16-Last incubator on right side of Trough 1; Replicant #3. Units for values are C.
NUMBER
C
12
Down_32B_Rep_1
NUMBER
No
No
Active
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 1-First trough receiving chilled water, Incubator 32-Last incubator on left side of Trough 1; Replicant #1. Units for values are C.
NUMBER
C
13
Down_32B_Rep_2
NUMBER
No
No
Active
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 1-First trough receiving chilled water, Incubator 32-Last incubator on left side of Trough 1; Replicant #2. Units for values are C.
NUMBER
C
14
Down_32B_Rep_3
NUMBER
No
No
Active
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 1-First trough receiving chilled water, Incubator 32-Last incubator on left side of Trough 1; Replicant #3. Units for values are C.
NUMBER
C
gov.noaa.nmfs.inport:35537
Jeffrey Cowen
2016-11-04T15:24:23
SysAdmin InPortAdmin
2022-08-09T17:11:16
2018-02-27
Northwest Fisheries Science Center
NWFSC
2725 Montlake Boulevard East
Seattle
WA
98112
USA
206-860-3200
http://www.nwfsc.noaa.gov
1001
Public
No
2018-02-27
1 Year
2019-02-27