Variation of Temperature in Incubation System Following Pump Failure with no Water Reservoir Trough 3 Incubators 1 and 17
Entity (ENT) | Northwest Fisheries Science Center (NWFSC)GUID: gov.noaa.nmfs.inport:37554 | Updated: August 9, 2022 | Published / External
-
View As
- Full List View
- Printable Form
- EXPORTS
- InPort XML
- View in Hierarchy
Summary
Trough 3, Incubators 1 and 17.
DescriptionTrough 3, Incubators 1 and 17.
Entity Information
Entity Type
Spreadsheet
Data Attribute / Type | Description |
---|---|
Count
NUMBER |
Measurement counter. Units for values are #. |
Data/Time
DATE |
Time of measurement. Units for values are days and minutes. |
Up_1B_Rep_1
NUMBER |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #1. Units for values are C. |
Up_1B_Rep_2
NUMBER |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #2. Units for values are C. |
Up_1B_Rep_3
NUMBER |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #3. Units for values are C. |
Up_17B_Rep_1
NUMBER |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #1. Units for values are C. |
Up_17B_Rep_2
NUMBER |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #2. Units for values are C. |
Up_17B_Rep_3
NUMBER |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #3. Units for values are C. |
Down_1B_Rep_1
NUMBER |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #1. Units for values are C. |
Down_1B_Rep_2
NUMBER |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #2. Units for values are C. |
Down_1B_Rep_3
NUMBER |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #3. Units for values are C. |
Down_17B_Rep_1
NUMBER |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #1. Units for values are C. |
Down_17B_Rep_2
NUMBER |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #2. Units for values are C. |
Down_17B_Rep_3
NUMBER |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #3. Units for values are C. |
Child Items
No Child Items for this record.
Contact Information
No contact information is available for this record.
Please contact the owner organization (NWFSC) for inquiries on this record.
Item Identification
Title: | Variation of Temperature in Incubation System Following Pump Failure with no Water Reservoir Trough 3 Incubators 1 and 17 |
---|---|
Short Name: | Variation of Temperature in Incubation System Following Pump Failure with no Water Reservoir Trough 3 Incubators 1 and 17 |
Status: | Planned |
Abstract: |
Trough 3, Incubators 1 and 17. |
Entity Information
Entity Type: | Spreadsheet |
---|---|
Active Version?: | Yes |
Schema Name: | PARR |
Description: |
Trough 3, Incubators 1 and 17. |
Data Attributes
Attribute Summary
Name | Type | Description | ||
---|---|---|---|---|
100
|
Count | NUMBER | Measurement counter. Units for values are #. | |
100
|
Data/Time | DATE | Time of measurement. Units for values are days and minutes. | |
100
|
Up_1B_Rep_1 | NUMBER | Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #1. Units for values are C. | |
100
|
Up_1B_Rep_2 | NUMBER | Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #2. Units for values are C. | |
100
|
Up_1B_Rep_3 | NUMBER | Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #3. Units for values are C. | |
100
|
Up_17B_Rep_1 | NUMBER | Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #1. Units for values are C. | |
100
|
Up_17B_Rep_2 | NUMBER | Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #2. Units for values are C. | |
100
|
Up_17B_Rep_3 | NUMBER | Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #3. Units for values are C. | |
100
|
Down_1B_Rep_1 | NUMBER | Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #1. Units for values are C. | |
100
|
Down_1B_Rep_2 | NUMBER | Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #2. Units for values are C. | |
100
|
Down_1B_Rep_3 | NUMBER | Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #3. Units for values are C. | |
100
|
Down_17B_Rep_1 | NUMBER | Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #1. Units for values are C. | |
100
|
Down_17B_Rep_2 | NUMBER | Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #2. Units for values are C. | |
100
|
Down_17B_Rep_3 | NUMBER | Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #3. Units for values are C. |
Attribute Details
Count
Seq. Order: | 1 |
---|---|
Data Storage Type: | NUMBER |
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Measurement counter. Units for values are #. |
General Data Type: | NUMBER |
Unit of Measure: | # |
Data/Time
Seq. Order: | 2 |
---|---|
Data Storage Type: | DATE |
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Time of measurement. Units for values are days and minutes. |
General Data Type: | DATE |
Unit of Measure: | days and minutes |
Up_1B_Rep_1
Seq. Order: | 3 |
---|---|
Data Storage Type: | NUMBER |
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #1. Units for values are C. |
General Data Type: | NUMBER |
Unit of Measure: | C |
Up_1B_Rep_2
Seq. Order: | 4 |
---|---|
Data Storage Type: | NUMBER |
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #2. Units for values are C. |
General Data Type: | NUMBER |
Unit of Measure: | C |
Up_1B_Rep_3
Seq. Order: | 5 |
---|---|
Data Storage Type: | NUMBER |
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #3. Units for values are C. |
General Data Type: | NUMBER |
Unit of Measure: | C |
Up_17B_Rep_1
Seq. Order: | 6 |
---|---|
Data Storage Type: | NUMBER |
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #1. Units for values are C. |
General Data Type: | NUMBER |
Unit of Measure: | C |
Up_17B_Rep_2
Seq. Order: | 7 |
---|---|
Data Storage Type: | NUMBER |
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #2. Units for values are C. |
General Data Type: | NUMBER |
Unit of Measure: | C |
Up_17B_Rep_3
Seq. Order: | 8 |
---|---|
Data Storage Type: | NUMBER |
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Failure of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #3. Units for values are C. |
General Data Type: | NUMBER |
Unit of Measure: | C |
Down_1B_Rep_1
Seq. Order: | 9 |
---|---|
Data Storage Type: | NUMBER |
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #1. Units for values are C. |
General Data Type: | NUMBER |
Unit of Measure: | C |
Down_1B_Rep_2
Seq. Order: | 10 |
---|---|
Data Storage Type: | NUMBER |
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #2. Units for values are C. |
General Data Type: | NUMBER |
Unit of Measure: | C |
Down_1B_Rep_3
Seq. Order: | 11 |
---|---|
Data Storage Type: | NUMBER |
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 1-First incubator on right side of Trough 3; Replicant #3. Units for values are C. |
General Data Type: | NUMBER |
Unit of Measure: | C |
Down_17B_Rep_1
Seq. Order: | 12 |
---|---|
Data Storage Type: | NUMBER |
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #1. Units for values are C. |
General Data Type: | NUMBER |
Unit of Measure: | C |
Down_17B_Rep_2
Seq. Order: | 13 |
---|---|
Data Storage Type: | NUMBER |
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #2. Units for values are C. |
General Data Type: | NUMBER |
Unit of Measure: | C |
Down_17B_Rep_3
Seq. Order: | 14 |
---|---|
Data Storage Type: | NUMBER |
Required: | No |
Primary Key: | No |
Status: | Active |
Description: |
Water temperature, Bottom Location, 4 channel Onset temperature logger; NR-Restart of chiller system without coldwater reservoir; Trough 3-Third trough receiving chilled water, Incubator 17-First incubator on left side of Trough 3; Replicant #3. Units for values are C. |
General Data Type: | NUMBER |
Unit of Measure: | C |
Catalog Details
Catalog Item ID: | 37554 |
---|---|
GUID: | gov.noaa.nmfs.inport:37554 |
Metadata Record Created By: | Jeffrey W Cowen |
Metadata Record Created: | 2017-04-03 14:18+0000 |
Metadata Record Last Modified By: | SysAdmin InPortAdmin |
Metadata Record Last Modified: | 2022-08-09 17:11+0000 |
Metadata Record Published: | 2018-02-27 |
Owner Org: | NWFSC |
Metadata Publication Status: | Published Externally |
Do Not Publish?: | N |
Metadata Last Review Date: | 2018-02-27 |
Metadata Review Frequency: | 1 Year |